Nuneaton · Atherstone · Bedworth · North Warwickshire

EICR Testing in Nuneaton & Atherstone

Commercial EICR and fixed wire testing, emergency lighting certification and thermal imaging surveys for businesses, schools, facilities managers and landlords across Nuneaton, Atherstone, Bedworth and North Warwickshire. Testing is booked around your working hours, including evenings, nights and weekends.

  • Evening, overnight & weekend testing
  • Full RAMS for every site
  • Calls answered 24/7

Warwickshire compliance, covered

One contractor for all three tests.
EICR / Fixed Wire TestingCommercial, industrial & rented property
Emergency Lighting (EML)Annual duration test & certificate
Thermal Imaging SurveysScanned live, no shutdown needed
See what each test covers
NICEIC Approved ContractorNICEIC Domestic Installer
  • DBS-Checked Engineers
  • SafeContractor
  • 200+ Google Reviews
  • Out-of-Hours Testing
  • Full RAMS Provided
Testing across North Warwickshire

Electrical testing for Nuneaton & Atherstone businesses

Nuneaton and Atherstone sit on one of the Midlands' busiest commercial corridors. The A5, M6 junction 3, the M69 and the A444 serve business parks such as Bermuda Park, engineering and automotive research around MIRA Technology Park, and a growing number of distribution warehouses. Alongside them are town-centre shops, offices, schools and care homes.

Whether your building is a modern logistics shed or a converted older property in Atherstone's historic Long Street, regular EICR testing confirms the wiring is safe. Emergency lighting certification keeps escape routes compliant, and thermal imaging spots overheating connections before they fail.

We test commercial and rented properties across the area, including:

  • Nuneaton
  • Atherstone
  • Bedworth
  • Attleborough
  • Stockingford
  • Camp Hill
  • Galley Common
  • Weddington
  • Whitestone
  • Chilvers Coton
  • Hartshill
  • Mancetter
  • Grendon
  • Bulkington
  • Polesworth
Business as usual

Testing booked around your hours

We agree an isolation plan before we start and test one circuit at a time, keeping critical equipment live where possible. Most commercial work is done when your premises are quiet.

EveningsShops, offices & surgeries
OvernightDistribution & 24-hour sites
WeekendsManufacturing & engineering
HolidaysSchools & academies

Premises we test across Nuneaton & Atherstone

From a shop on Long Street to a business park unit off the M6.

Engineering & Manufacturing

Engineering, automotive and manufacturing businesses with three-phase plant, tested at weekends or during planned shutdowns.

Distribution & Logistics

Warehouses along the A5 and M69, with high-bay lighting, loading docks and long escape routes to certify.

Business Parks & Offices

Business park units and town-centre offices, tested out of hours with IT and access control kept running.

Town Centre Retail

Shops, cafés, pubs and restaurants in Nuneaton, Bedworth and Atherstone, tested before opening or after closing.

Care Homes & Healthcare

Care homes, surgeries and clinics, where testing is carefully planned around residents and patients.

Landlords & Letting Agents

Rented homes and HMOs across Nuneaton, Bedworth and North Warwickshire, with access arranged for you.

Fixed wire testing

Commercial EICR Testing in Nuneaton & Atherstone

An Electrical Installation Condition Report (EICR) is a thorough inspection and test of your fixed wiring, from the incoming supply through every distribution board to each final circuit. It confirms whether your installation is safe to keep using, and gives you the report insurers and auditors expect under the Electricity at Work Regulations 1989.

  • Main switchgear, distribution boards and sub-mains inspected
  • Three-phase supplies, machinery circuits and isolators tested
  • Protective devices, RCDs, earthing and bonding verified
  • Scope and sampling agreed with you before we start
  • Site-specific RAMS; isolations planned around your shifts
  • Clear report with every observation coded and explained

Problems found on test? As part of Able Electric, our electricians can carry out the repairs. Electrical installations & repairs since 2009.

C1
Danger present. Made safe on the day.
C2
Potentially dangerous. Urgent remedial work.
C3
Improvement recommended.
FI
Further investigation required.

Any C1, C2 or FI means an "Unsatisfactory" report. We explain each one and quote to put it right.

How often do Nuneaton & Atherstone premises need an EICR?

3 yearsFactories, workshops & industrial units
5 yearsWarehouses, offices & retail
5 yearsSchools, care homes & public buildings
1 yearLeisure centres & swimming pools
5 yearsRented homes & HMOs (legal requirement)

Maximum recommended intervals based on IET Guidance Note 3. Your insurer, or the condition and use of the installation, may call for shorter intervals.

EML testing

Emergency Lighting Testing & Certification

When the power goes, everyone in your building, from warehouse staff to care home residents, needs a clearly lit route to a safe exit. Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person must make sure emergency lighting is maintained and tested, and BS 5266-1 sets out how.

  • Annual full-duration test of every luminaire and exit sign
  • Escape routes, stairwells, high-risk task areas and open areas checked
  • Self-contained and central battery systems
  • Duration tests out of hours, so the building isn't left unprotected while batteries recharge
  • Certificate and updated log book for your fire risk assessment

Failed fittings or batteries? We replace and retest them, and can upgrade old fittings to LED. Repairs carried out by Able Electric.

Monthly

Short functional test. A brief check that each fitting switches to battery. Usually done in-house; we can show your staff how.

Annual

Full rated-duration test. Usually 3 hours on battery. Carried out and certified by us.

Always

Log book kept up to date. Fire officers and insurers will ask to see it.

Infrared surveys

Thermal Imaging Surveys in North Warwickshire

A thermal camera shows heat the eye can't see. We scan your switchgear, distribution boards, busbars and machinery connections while they run under full production load, with no shutdown and no lost output, and find faults before they cause a breakdown or a fire.

Loose or corroded terminations
Overloaded circuits & cables
Unbalanced three-phase loads
Failing breakers, fuses & contactors
  • Report with thermal and standard images, temperatures and priority ratings
  • Ideal for production lines, compressors, extraction and plant rooms
  • Supports insurer requirements and planned preventative maintenance
  • Works alongside your EICR, or in the years between tests

Hotspots found? Our electricians can fix the fault and rescan to confirm. Find out more about Able Electric.

CoolHot

Illustration. Your report includes the actual thermal images from your site.

Since 2009

Test failed? We'll put it right, as part of Able Electric

EICR Testing is part of Able Electric, who have been carrying out electrical installations and repairs across the Midlands since 2009. When your EICR, emergency lighting test or thermal survey finds a problem, the same NICEIC-approved team can fix it. There's no second contractor to find and nobody to re-brief.

  1. On the dayC1 dangers made safe before we leave
  2. ExplainedEvery finding in plain English
  3. Itemised quoteA fixed price for each repair
  4. ConfirmedRepaired, retested & certified
Nuneaton & Atherstone FAQs

EICR testing in Nuneaton & Atherstone: your questions answered

What businesses, facilities managers, schools and landlords across North Warwickshire ask us before booking.

Speak to us 02476 309621 Calls answered 24/7 Request a free quote
Do you cover Nuneaton, Atherstone and Bedworth?

Yes. We test commercial and rented properties across Nuneaton, Bedworth, Atherstone and North Warwickshire, including Attleborough, Stockingford, Camp Hill, Galley Common, Weddington, Hartshill, Mancetter, Grendon, Bulkington and Polesworth. We're NICEIC Approved and SafeContractor Accredited.

Can testing be done outside our opening hours?

Yes. Most of our commercial testing in the area is done in the evening, overnight or at weekends. We isolate circuits one at a time to a plan agreed with you, so critical equipment such as servers, refrigeration and alarms can stay live wherever possible.

How often does a business in Nuneaton need an EICR?

Maximum recommended intervals are five years for offices, shops, warehouses and schools, and three years for industrial premises. Leisure facilities such as swimming pools are every year. Insurers may set shorter intervals, and your report recommends the next test date.

Do you test warehouses along the A5 and M69?

Yes. Logistics and distribution sites have long cable runs, high-bay lighting, loading docks and charging areas. We test zone by zone, often overnight, and report each area separately so any remedial work is easy to plan.

Do you test older buildings in Atherstone?

Yes. Older and converted buildings often have wiring from several eras, with alterations added over time. An EICR identifies what's safe, what needs attention and what should be upgraded, and we explain the findings in plain English.

Do you test emergency lighting?

Yes. We carry out the annual full-duration test required by BS 5266-1 across Nuneaton & Atherstone premises, checking every fitting and exit sign along escape routes, stairwells and open areas. You get a certificate and an updated log book. Failed fittings and batteries can be replaced, and older fittings upgraded to LED.

Will a thermal imaging survey need a shutdown?

No. Thermal imaging has to be done while the installation is under normal load, so there's no shutdown. We scan switchgear, distribution boards and connections for loose terminations, overloading, unbalanced phases and failing breakers, and report each hotspot with thermal images, temperatures and a priority rating.

Can you combine EICR, emergency lighting and thermal imaging?

Yes. Thermal imaging is done during the working day while you're running, with the EICR and emergency lighting duration test that evening or weekend. You get one set of RAMS, one contact and one combined list of any remedial work.

Do you work with facilities managers and multi-site companies?

Yes. We provide site-specific RAMS before attendance, SafeContractor accreditation for supplier approval, testing programmed across all your sites, consistent reports, and remedial quotes itemised by observation code for budget sign-off.

I'm a landlord in Nuneaton & Atherstone. What do I need to do?

Private landlords in England must have rented homes inspected and tested at least every five years, give tenants a copy of the report within 28 days, and give it to new tenants before they move in. Your local council (Nuneaton and Bedworth, or North Warwickshire) can ask for a copy, which must be supplied within 7 days. Any remedial work must be completed within 28 days. We test single lets, HMOs and portfolios across Nuneaton & Atherstone, and can arrange access with tenants or your agent.

What happens if the test finds problems?

Immediate dangers (C1) are made safe on the day. Everything else is explained in plain English and priced item by item. EICR Testing is part of Able Electric, carrying out electrical installations and repairs since 2009, so our own electricians can complete the work, out of hours if needed, and confirm it in writing.

How do I get a quote for my Nuneaton & Atherstone premises?

Call 02476 309621 (answered 24/7) or use the quote form below. Tell us the type of premises, roughly how many distribution boards or emergency light fittings there are, and any times to avoid, and we'll send you a fixed price.

Local EICR testing

EICR Testing Across the Midlands

As well as Nuneaton and Atherstone, we test commercial and rented properties throughout Warwickshire, the West Midlands, Staffordshire and Worcestershire. Choose your nearest area below.

Nearby

Coventry

Commercial EICR testing, fixed wire inspections and electrical compliance for businesses, landlords and property owners across Coventry.

Coventry Testing →
Nearby

Coleshill & Erdington

EICR testing and electrical inspections for commercial premises, landlords and property owners across Coleshill and Erdington.

Coleshill & Erdington Testing →
Nearby

Lichfield & Burntwood

Electrical inspection and testing for businesses, landlords and properties across Lichfield, Burntwood and surrounding Staffordshire.

Lichfield & Burntwood Testing →
Nearby

Solihull & Knowle

Electrical inspection and EICR testing for businesses, landlords and properties throughout Solihull, Knowle and surrounding areas.

Solihull & Knowle Testing →

Based in Tamworth, minutes from North Warwickshire

Atherstone and Nuneaton are just down the A5 from our Tamworth base, so evening, overnight and weekend testing is easy to arrange.

EICR Testing Tamworth →
Free quote

Get a quote for your Nuneaton or Atherstone premises

Tell us about the site and what you need tested. We'll come back to you with a clear, fixed quote.

  1. 1Send the form. It takes about a minute.
  2. 2We'll contact you to confirm the scope and access.
  3. 3You get a fixed quote, with RAMS for commercial sites.
Prefer to talk? 02476 309621 Calls answered 24/7

Office hours Mon–Fri 8am–5pm · office@ableelectric.co.uk

Call Us