Burton upon Trent · Branston · Uttoxeter · Swadlincote

EICR Testing in Burton upon Trent

EICRs, emergency lighting and thermal imaging for breweries, food producers, warehouses, offices, schools and landlords across Burton upon Trent, Branston and East Staffordshire. Testing around your production schedule.

  • Evening, overnight & weekend testing
  • Full RAMS for every site
  • Calls answered 24/7

Burton compliance, covered

Book one test, or all three in one visit.
EICR / Fixed Wire TestingCommercial, industrial & rented property
Emergency Lighting (EML)Annual duration test & certificate
Thermal Imaging SurveysScanned live, no shutdown needed
See what each test covers
NICEIC Approved ContractorNICEIC Domestic Installer
  • DBS-Checked Engineers
  • SafeContractor
  • 200+ Google Reviews
  • Out-of-Hours Testing
  • Full RAMS Provided
Testing across Burton upon Trent

Testing for Burton's brewing, food and logistics businesses

Burton upon Trent is famous for brewing, and it's still home to major breweries and food producers, alongside large distribution parks at Centrum 100 and Branston and the A38 and A50 corridors, plus offices, schools, care homes and rented homes.

Process plant, refrigeration, wash-down areas and 24-hour operations need careful planning. We carry out EICRs around your production, use thermal imaging to find hotspots while you run, and certify emergency lighting across large sites.

We test commercial and rented properties across the area, including:

  • Burton upon Trent
  • Branston
  • Stretton
  • Winshill
  • Horninglow
  • Stapenhill
  • Tutbury
  • Barton-under-Needwood
  • Uttoxeter
  • Swadlincote
No disruption

We test when it suits you

An EICR means switching circuits off one at a time. We agree an isolation plan with you first and keep critical equipment, IT, refrigeration and alarms live wherever we can.

EveningsOffices, shops & surgeries
OvernightRetail, hospitality & 24-hour sites
WeekendsFactories & warehouses
HolidaysSchools & colleges

Premises we test across Burton upon Trent

Every type of commercial and rented building, from a single unit to a multi-site estate.

Food & Drink Production

Breweries, bakeries and food factories with process plant, refrigeration and wash-down areas, tested to your hygiene rules.

Warehouses & Distribution

High-bay lighting, racking, loading bays and long escape routes, tested zone by zone around your operations.

Manufacturing & Engineering

Factories, machine shops and fabricators with three-phase plant, tested at weekends or during planned shutdowns.

Offices & Business Units

Offices, business centres and managed units, tested out of hours with servers and IT kept running.

Schools & Colleges

Schools, academies, nurseries and colleges, tested in the holidays with access planned around the timetable.

Landlords & Letting Agents

Rented homes, HMOs and flats, with access arranged with tenants or your letting agent and reports sent straight to you.

Fixed wire testing

Commercial EICR Testing in Burton upon Trent

An Electrical Installation Condition Report (EICR) is a full inspection and test of your fixed wiring, from the incoming supply and distribution boards to every final circuit. It shows whether your installation is safe to keep using, and gives you the evidence insurers, landlords and auditors expect under the Electricity at Work Regulations 1989.

  • Main switchgear, distribution boards and sub-mains inspected
  • Three-phase supplies, machinery circuits and isolators tested
  • Protective devices, RCDs, earthing and bonding verified
  • Scope and sampling agreed with you before we start
  • Site-specific RAMS; isolations planned around your shifts
  • Clear report with every observation coded and explained

Problems found on test? As part of Able Electric, our electricians can carry out the repairs. Electrical installations & repairs since 2009.

C1
Danger present. Made safe on the day.
C2
Potentially dangerous. Urgent remedial work.
C3
Improvement recommended.
FI
Further investigation required.

Any C1, C2 or FI means an "Unsatisfactory" report. We explain each one and quote to put it right.

How often do Burton upon Trent premises need an EICR?

3 yearsFactories, breweries & food production
5 yearsWarehouses, offices & retail
5 yearsSchools & care homes
1 yearLeisure centres & swimming pools
5 yearsRented homes & HMOs (legal requirement)

Maximum recommended intervals based on IET Guidance Note 3. Your insurer, or the condition and use of the installation, may call for shorter intervals.

EML testing

Emergency Lighting Testing & Certification

When the power fails, staff, customers and visitors need a clear, lit route to a safe exit. Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person must make sure emergency lighting is maintained and tested, and BS 5266-1 sets out how.

  • Annual full-duration test of every luminaire and exit sign
  • Escape routes, stairwells, high-risk task areas and open areas checked
  • Self-contained and central battery systems
  • Duration tests out of hours, so the building isn't left unprotected while batteries recharge
  • Certificate and updated log book for your fire risk assessment

Failed fittings or batteries? We replace and retest them, and can upgrade old fittings to LED. Repairs carried out by Able Electric.

Monthly

Short functional test. A brief check that each fitting switches to battery. Usually done in-house; we can show your staff how.

Annual

Full rated-duration test. Usually 3 hours on battery. Carried out and certified by us.

Always

Log book kept up to date. Fire officers and insurers will ask to see it.

Infrared surveys

Thermal Imaging Surveys in Burton upon Trent

A thermal camera shows heat the eye can't see. We scan your switchgear, distribution boards, busbars and machinery connections while they run under full production load, with no shutdown and no lost output, and find faults before they cause a breakdown or a fire.

Loose or corroded terminations
Overloaded circuits & cables
Unbalanced three-phase loads
Failing breakers, fuses & contactors
  • Report with thermal and standard images, temperatures and priority ratings
  • Ideal for production lines, compressors, extraction and plant rooms
  • Supports insurer requirements and planned preventative maintenance
  • Works alongside your EICR, or in the years between tests

Hotspots found? Our electricians can fix the fault and rescan to confirm. Find out more about Able Electric.

CoolHot

Illustration. Your report includes the actual thermal images from your site.

Since 2009

Test failed? We'll put it right, as part of Able Electric

EICR Testing is part of Able Electric, who have been carrying out electrical installations and repairs across the Midlands since 2009. When your EICR, emergency lighting test or thermal survey finds a problem, the same NICEIC-approved team can fix it. There's no second contractor to find and nobody to re-brief.

  1. On the dayC1 dangers made safe before we leave
  2. ExplainedEvery finding in plain English
  3. Itemised quoteA fixed price for each repair
  4. ConfirmedRepaired, retested & certified
Burton FAQs

EICR testing in Burton upon Trent: your questions answered

What businesses, facilities managers and landlords ask us before booking.

Speak to us 01543 728138 Calls answered 24/7 Request a free quote
Do you test breweries and food factories?

Yes. We work to your hygiene rules, permits and inductions, and plan isolations around production, cleaning and maintenance windows. Refrigeration and critical process plant stay live wherever possible.

Can you carry out thermal imaging on process plant?

Yes. Thermal surveys are done while your plant is running under load, scanning switchgear, motor control centres and connections. Each hotspot is reported with images, temperatures and a priority rating.

Which areas do you cover?

Burton upon Trent, Branston, Stretton, Winshill, Stapenhill, Tutbury, Barton-under-Needwood, Uttoxeter and Swadlincote. We're NICEIC Approved and SafeContractor Accredited.

Do you test emergency lighting?

Yes. We carry out the annual full-duration test required by BS 5266-1 across Burton premises, checking every fitting and exit sign along escape routes, stairwells and open areas. You get a certificate and an updated log book. Failed fittings and batteries can be replaced, and older fittings upgraded to LED.

Will a thermal imaging survey need a shutdown?

No. Thermal imaging has to be done while the installation is under normal load, so there's no shutdown. We scan switchgear, distribution boards and connections for loose terminations, overloading, unbalanced phases and failing breakers, and report each hotspot with thermal images, temperatures and a priority rating.

Can you combine EICR, emergency lighting and thermal imaging?

Yes. Thermal imaging is done during the working day while you're running, with the EICR and emergency lighting duration test that evening or weekend. You get one set of RAMS, one contact and one combined list of any remedial work.

Do you work with facilities managers and multi-site companies?

Yes. We provide site-specific RAMS before attendance, SafeContractor accreditation for supplier approval, testing programmed across all your sites, consistent reports, and remedial quotes itemised by observation code for budget sign-off.

I'm a landlord in Burton. What do I need to do?

Private landlords in England must have rented homes inspected and tested at least every five years, give tenants a copy of the report within 28 days, and give it to new tenants before they move in. East Staffordshire Borough Council can ask for a copy, which must be supplied within 7 days. Any remedial work must be completed within 28 days. We test single lets, HMOs and portfolios across Burton, and can arrange access with tenants or your agent.

What happens if the test finds problems?

Immediate dangers (C1) are made safe on the day. Everything else is explained in plain English and priced item by item. EICR Testing is part of Able Electric, carrying out electrical installations and repairs since 2009, so our own electricians can complete the work, out of hours if needed, and confirm it in writing.

How do I get a quote for my Burton premises?

Call 01543 728138 (answered 24/7) or use the quote form below. Tell us the type of premises, roughly how many distribution boards or emergency light fittings there are, and any times to avoid, and we'll send you a fixed price.

Local EICR testing

EICR Testing Across the Midlands

As well as Burton upon Trent, we test commercial and rented properties throughout the West Midlands, Staffordshire, Warwickshire and Worcestershire. Choose your nearest area below.

Nearby

Tamworth

Our home town. EICR, emergency lighting and thermal imaging for Tamworth businesses, schools and landlords.

Tamworth Testing →
Nearby

Lichfield & Burntwood

Electrical inspection and testing for businesses, landlords and properties across Lichfield, Burntwood and surrounding Staffordshire.

Lichfield & Burntwood Testing →
Nearby

Stafford

Commercial EICR, emergency lighting and thermal imaging for Stafford businesses, schools and landlords.

Stafford Testing →
Nearby

Cannock & Brownhills

EICRs and emergency lighting for warehouses, shops and landlords in Cannock, Hednesford, Brownhills and Norton Canes.

Cannock & Brownhills Testing →
Nearby

Nuneaton & Atherstone

Electrical inspection, EICR testing and commercial compliance services across Nuneaton, Atherstone and surrounding Warwickshire.

Nuneaton & Atherstone Testing →
Nearby

Coleshill & Erdington

EICR testing and electrical inspections for commercial premises, landlords and property owners across Coleshill and Erdington.

Coleshill & Erdington Testing →

Based in Tamworth, testing across Burton upon Trent

Burton is a short drive up the A38 from our Tamworth base, so evening, overnight and weekend testing is easy to arrange.

EICR Testing Tamworth →
Free quote

Get a quote for your Burton upon Trent premises

Tell us about the site and what you need tested. We'll come back to you with a clear, fixed quote.

  1. 1Send the form. It takes about a minute.
  2. 2We'll contact you to confirm the scope and access.
  3. 3You get a fixed quote, with RAMS for commercial sites.
Prefer to talk? 01543 728138 Calls answered 24/7

Office hours Mon–Fri 8am–5pm · office@ableelectric.co.uk

Call Us